SSA-S1000
Standalone RFID
Access Controller
user manual
imagine the possibilities
Thank you for purchasing this Samsung product.
To receive more complete service,
please visit our website.
5. Keep out of direct sunlight and heat radiation sources. It may cause fire.
6. Install it in a place with good ventilation.
7. Avoid aiming the controller directly towards extremely bright objects such as sun.
8. Apparatus shall not be exposed to dripping or splashing and no objects filled with liquids, such as vases, shall be
placed on the apparatus.
9. The Mains plug is used as a disconnect device and shall stay readily operable at any time.
FCC Statement
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions :
1) This device may not cause harmful interference, and
2) This device must accept any interference received including interference that may cause undesired operation.
Caution
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part
15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in ac-
cordance with the instruction manual, may cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference in which case the user will be required to
correct the interference at his own expense.
IMPORTANT SAFETY INSTRUCTIONS
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
8. Do not install near any heat sources such as radiators, heat registers, or other apparatus (including amplifiers) that
produce heat.
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one
wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third
prong is provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for
replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the
point where they exit from the apparatus.
11. Only use attachments/accessories specified by the manufacturer.
12. Use only with cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with
the apparatus.
13. Unplug this apparatus when a card is used. Use caution when moving the cart/ apparatus
combination to avoid injury from tip-over.
14. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any
way, such as powersupply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus,
the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
English3
contents
5
6
7
8
8
Feature
What’s included
At a Glance
Cable Color Scheme
Cable Selection
PRODUCT INTRODUCTION
5
9
9
Installation
Bypass Diode Connection
INSTALLATION AND EXTERNAL
CONNECTION
10 I/O Connection
9
12 Initializing the system by short-circuiting
12 Basic Operations
13 To register /delete Master ID
13 To register/delete ID card
SYSTEM INITIALIZATION & BASIC
OPERATIONS
12
15 Product Specifications
PRODUCT SPECIFICATIONS
15
product introduction
FEATURE
This product is designed for use with one-door access control for security applications. With its compact design, you can
install this product on the wall or a doorframe; Its epoxy molding guarantees stable operation in a challenging environment.
This product enables you to control the door using the user card and provides a simple method to register or delete cards,
and initialize the system, which is, one of the most convenient and safest door controller.
And it is also featured by the 2-color LED indicator and the internal buzzer, enabling you to easily check the current mode
and operation of the door lock.
◆
◆
◆
◆
◆
◆
◆
125 kHz Proximity Access Controller
Up to 512 users including one Master ID can be registered
Standalone (no application S/W required)
Direct Control of the Door Lock
Can select a lock device type from Power Fail Safe and Power Fail Secure
Epoxy Molding
Weatherproof
English5
product introduction
WHAT’S INCLUDED
Check if the following items are included in the product package.
tGj
Master Card (x1)
Keytag (x5)
Main Module
Bezel
xGn
3.5 x 40mm Screws (x2)
3.5 x 25mm Screws (x2)
6 x 30mm Plastic Anchors (x2)
Diode (X 2)
(UF4004, 1N4001~4007)
Quick Guide
CD Manual
6_ Product Introduction
AT A GLANCE
Front/Rear
3
4
5
LED
Displays the system operation status using red and green indicators.
Fixing hole for wall-mounting.
1
Fixing Hole
2
Connection Cable
Used to connect to the power or I/O cable.
Port used to upgrade the firmware.
Piezo buzzer.
3
4
5
Program Port
Buzzer
English7
product introduction
CABLE COLOR SCHEME
Item
Cable Color
Red
Signal Line
DC+12V
Description
+12V supplied
Power
Black
GND
Earth-Grounding for Power
Select a Lock Type
Yellow
Blue
AUX INPUT#1
Door Contact Sensor
Exit Button
Input
Output
Door Sensor Connection Port
Exit Button Connection Port
Green
Alarm Device Connection
Port
Purple
White
Alarm Out
Door Lock device connection
port
Door Lock Out
Gray
Orange
Brown
Not used
CABLE SELECTION
Item
Cable Type
Power (DC +12V)
Belden #9409, 18 AWG 2 Conductor, Unshielded
Belden #9512, 22 AWG 4 Conductor, Shielded
1
Door Contact Sensor
Exit Button
Sensor Input
2
Belden #9514, 22 AWG 8 Conductor, Shielded
Belden #9409, 18AWG 2 Conductor, Unshielded
Door Lock
3
Alarm Device
8_ Product Introduction
installation and external connection
INSTALLATION
10
6-32 hole
6-32 or M3 Screws
1/2” hole
6-32 hole
Reader
Module
8.5
- On a doorframe or the wall
1. Drill a 1/2-inch (12.7 mm) hole onto the center of the doorframe or the wall where SSA-S1000 is installed, which
makes room for the cable of the reader module.
2. Drill two 0.3-inch (7.62 mm) holes: one on the point of 0.39 inch (10 mm) horizontally to the right, 1.74 inch
(44.4 mm) vertically up from the center hole, and one on the point of 0.33 inch (8.5 mm) horizontally to the left,
0.3 inch (7.62 mm) vertically down from the point.
3. Insert the reader module cable into the center hole and secure the module using two screws inserted in the
upper right and the bottom left corner, respectively.
4. Insert the bezel of SSA-S1000 into the reader module and attach it by pressing the upper and lower corner of
the bezel.
BYPASS DIODE CONNECTION
If you connected an inductor (door lock or alarm device) to the output relay, there should occur a voltage surge while the
inductor was between turning on and turning off. If you do not connect a reverse diode to the relay, the voltage surge will
cause damage to the electric circuit of the controller. To reduce this surge, it is recommended to connect the bypass
diode to the relay.
English9
installation and external connection
I/O CONNECTION
Input Connection
DOOR CONTACT (blue)
Door Contact Sensor
EXIT BUTTON
(green)
Exit Button
PUSH
DC +12V
GND
GND
(black)
DC +12V
(red)
DC 12V(+) POWER
- To connect the power supply unit
1. Connect the DC+12V to the red line.
2. Connect GND to the black line.
- To connect the Door Contact Sensor
1. Connect the COM port of the sensor to the blue line.
2. Connect the NO port of the sensor with the GND line.
- To connect the Exit Button
1. Connect one end of the button to the green line.
2. Connect the other end of the button to GND.
10_ Installation and External Connection
Output Connection
DOOR LOCK OUT
(white)
Door Lock
ALARM OUT
(purple)
Alarm Device
Lock Type Select
(yellow)
Cathode
Anode
1N4004 ~ 1N4007 or equiv.
DC +12V
GND
DC 12V(+) POWER
- To connect the power supply unit
1. Connect the DC+12V to the red line.
2. Connect GND to the black line.
- To connect the door lock device
1. Connect the plus(+) line of the lock device to DC+12V.
2. Connect the minus(-) line of the lock device to the white line.
- To connect the alarm device
1. Connect the plus(+) line of the alarm device to DC+12V.
2. Connect the minus(-) line of the alarm device to the purple line.
- To specify the lock type
POWER FAIL SAFE: Connect the yellow line to GND.
POWER FAIL SECURE: Leave the yellow line in the floating state.
English11
system initialization & basic operations
INITIALIZING THE SYSTEM BY SHORT-CIRCUITING
Short-Circuit
1. Turn off the product and short-circuit three lines: white line of
the door lock device, green line of the Exit button, and yellow
line of the lock type.
White
Door Lock
2. When you turn the product back on, all of the LED indicators
Green
turn red or green, repeat turning on/off twice before being
Exit Button
completely turned off.
Yellow
Lock Type
3. In the power-off condition, all LED indicators turn green
bottom up in sequence.
4. When you hear a beep 4 times, that indicates that the
initialization is completed.
Black
Power
Red
If you initialize the system, all of the data settings will return to the factory default.
M
BASIC OPERATIONS
When the power is supplied
1. All of the LED indicators will turn red or green, and repeat turning ON/OFF twice before being completely turned
OFF. In the power-off condition, all LED indicators turn red bottom up in sequence.
2. You will hear a beep once.
When you present a registered card to the product or press the Exit button
1. All LED indicators turn from red to green, and turn off top down in sequence before turning back red.
2. Then, the door stays open for the specified time with the upper two indicators turning green, which indicates the
door is open.
3. You will hear a beep once.
When you present an unregistered card to the product
1. All LED indicators turn red, and repeat turning on/off twice before staying in ON.
2. You will hear a beep twice.
When you present a user card to the product while the door is open
1. The two LED indicators from the top stay green, indicating the door is open; in the mean time, the other
indicators reflect the authentication results.
12_ System Initialization & Basic Operations
TO REGISTER /DELETE MASTER ID
SSA-S1000
1. First turn off the product, and short-circuit two lines: purple line of
Cable
Alarm Out and blue line of the Door Contact Sensor.
Blue
2. When you turn the product back on, you will hear the beep twice while
all of the LED indicators turn red, and repeat turning on/off twice before
being completely ON; then the Master card will be deleted.
Yellow
Green
Purple
White
Short-Circuit
3. Upon deletion of the Master Card, you will hear a beep once and
all of the LED indicators toggle between green and red twice
before turning off; in this condition, they turn red from bottom up
in sequence.
Red
DC12V
Power
4. When the deletion is completed, turn off the product.
Connect the purple line of Alarm Out and the blue line of the Door
Contact Sensor back to their original ports, respectively.
Black
GND
5. When you turn the product back on, it recognizes and registers the first-read card as the Master Card. And
if you present a registered user card to the product upon deletion of the Master Card, that card will be
registered as the Master Card.
If you present a registered user card after the Master Card is deleted, that card will be registered as the Master Card.
M
TO REGISTER/DELETE ID CARD
1. If you present the Master Card to the product, it will sound the beep
once and the first three LED indicators from the top will turn green
from the top.
SSA-S1000
MASTER CARD
2. If you present a new user card to the product, it will sound the beep
once and all of the LED indicators except for the first three ones from
the top will turn from red to green. Then, they all turn off and turn
back on bottom up in sequence. When all of the LED indicators turn
back on, they will turn red except for the first three LED indicators
from the top . Then, the user card will be registered.
3. If you present a registered user card, the product will sound the beep twice and all LED indicators except for the
first 3 from the top will turn red, and repeat turning on/off twice before being completely ON. Then the user card
will be deleted.
4. When you present the Master Card to the product after the user card is deleted, the product will sound the
beep once and all of the LED indicators turn red, starting with the first three LED indicators from the top turning
from green to red.
If you present a registered user card after the Master Card is deleted, that card will be registered as the Master Card.
M
English13
troubleshooting
TROUBLESHOOTING
If the product does not function properly, please see the below for trouble shooting. If the trouble persists, please contact
the SAMSUNG Customer Service near you.
PROBLEM
SOLUTION
1) Check if the product works properly.
The user card is not deleted.
- If the product works properly and you have the Master Card
c Read the Master Card.
d Read the card to delete.
e Read the Master Card again to switch to normal mode.
f For more information about deleting user cards, refer to the ID registration and
deletion section in this manual.
- If you lost the Master Card
c Turn off the product and short-circuit the purple and blue lines, then turn the
product back on.
d The Master ID will be deleted with a flashing LED indicator and beep.
e When the Master card is deleted, turn off the product and restore the purple
and blue lines to their respective original positions.
f The very first card read by the product after turning on the product will be
registered as the Master Card.
g For deleting the ID once the Master Card is registered, refer to the ID
registration and deletion section in this manual.
h Turn off the product and short-circuit the purple and blue lines, then turn the
product back on.
i The Master ID will be deleted with a flashing LED indicator and beep.
j When the Master card is deleted, turn off the product and restore the purple
and blue lines to their respective original.
k The very first card read by the product after turning on the product will be
registered as the Master Card.
The Exit button does not work at all.
1) Check if the Exit button is connected to SSA-S1000 properly. (the Exit button
should be used with a NO-type button)
2) Check if the Exit button works normally.
- Check the connection cable between the Exit button and SSA-S1000 for any
disconnection or short-circuit.
- Try to connect the two lines on the Exit button.
c If SSA-S1000 responds when you press the Exit button
√ Replace the Exit button as it is defective.
d If SSA-S1000 does not respond at all
√ Initialize the product as it is damaged or malfunctions. (Initializing the product
will lose all user data.)
3) If the trouble persists after following the procedures above, contact a designated
service center.
14_ troubleshooting
product specifications
PRODUCT SPECIFICATIONS
Item
SSA-S1000
Users
512 Users
Power / Current
Reading Time (Card)
Door Open Time
Input Port
DC 12V / Max.110mA
30ms
5sec. (Fixed)
3ea: Exit Button, Door Sensor, Lock Type Select [Power fail Safe / Power Fail Secure]
2ea : TR Output / DC 12V. Rating Max. 300mA Alarm Output, DC 12V. Rating Max.
1A Lock Output
Output Port
LED Indicator
9 LED Indicators (Red and Green)
Piezo Buzzer
Beeper
Operating Temperature
Operating Humidity
Color / Material
-20°C to +50°C
10% to 90% Relative Humidity Non-Condensing
Silver with Black/ Polycarbonate
Dimension
(W x H x D(mm))
45.0 x 122.0 x 25.0
130g
Weight
English15
Correct Disposal of This Product (Waste Electrical & Electronic Equipment)
(Applicable in the European Union and other European countries with separate collection systems)
This marking on the product, accessories or literature indicates that the product and its electronic accessories (e.g.
charger, headset, USB cable) should not be disposed of with other household waste at the end of their working life. To
prevent possible harm to the environment or human health from uncontrolled waste disposal, please separate these
items from other types of waste and recycle them responsibly to promote the sustainable reuse of material resources.
Household users should contact either the retailer where they purchased this product, or their local government office, for
details of where and how they can take these items for environmentally safe recycling.
Business users should contact their supplier and check the terms and conditions of the purchase contract.
This product and its electronic accessories should not be mixed with other commercial wastes for disposal.
Correct disposal of batteries in this product
(Applicable in the European Union and other European countries with separate battery return systems.)
This marking on the battery, manual or packaging indicates that the batteries in this product should not be disposed of
with other household waste at the end of their working life. Where marked, the chemical symbols Hg, Cd or Pb indicate
that the battery contains mercury, cadmium or lead above the reference levels in EC Directive 2006/66. If batteries are
not properly disposed of, these substances can cause harm to human health or the environment.
To protect natural resources and to promote material reuse, please separate batteries from other types of waste and
recycle them through your local, free battery return system.
AB82-02558A
|