5. Keep out of direct sunlight and heat radiation sources. It may cause fire.  
6. Install it in a place with good ventilation.  
7. Avoid aiming the controller directly towards extremely bright objects such as sun.  
8. Apparatus shall not be exposed to dripping or splashing and no objects filled with liquids, such as vases, shall be  
placed on the apparatus.  
9. The Mains plug is used as a disconnect device and shall stay readily operable at any time.  
FCC Statement  
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions :  
1) This device may not cause harmful interference, and  
2) This device must accept any interference received including interference that may cause undesired operation.  
Caution  
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part  
15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when  
the equipment is operated in a commercial environment.  
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in ac-  
cordance with the instruction manual, may cause harmful interference to radio communications. Operation of this  
equipment in a residential area is likely to cause harmful interference in which case the user will be required to  
correct the interference at his own expense.  
IMPORTANT SAFETY INSTRUCTIONS  
1. Read these instructions.  
2. Keep these instructions.  
3. Heed all warnings.  
4. Follow all instructions.  
5. Do not use this apparatus near water.  
6. Clean only with dry cloth.  
7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.  
8. Do not install near any heat sources such as radiators, heat registers, or other apparatus (including amplifiers) that  
produce heat.  
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one  
wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third  
prong is provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for  
replacement of the obsolete outlet.  
10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the  
point where they exit from the apparatus.  
11. Only use attachments/accessories specified by the manufacturer.  
12. Use only with cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with  
the apparatus.  
13. Unplug this apparatus when a card is used. Use caution when moving the cart/ apparatus  
combination to avoid injury from tip-over.  
14. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any  
way, such as powersupply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus,  
the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.  
English3  
 
contents  
5
6
7
8
8
Feature  
What’s included  
At a Glance  
Cable Color Scheme  
Cable Selection  
PRODUCT INTRODUCTION  
5
9
9
Installation  
Bypass Diode Connection  
INSTALLATION AND EXTERNAL  
CONNECTION  
10 I/O Connection  
9
12 Initializing the system by short-circuiting  
12 Basic Operations  
13 To register /delete Master ID  
13 To register/delete ID card  
SYSTEM INITIALIZATION & BASIC  
OPERATIONS  
12  
15 Product Specifications  
PRODUCT SPECIFICATIONS  
15  
 
product introduction  
FEATURE  
This product is designed for use with one-door access control for security applications. With its compact design, you can  
install this product on the wall or a doorframe; Its epoxy molding guarantees stable operation in a challenging environment.  
This product enables you to control the door using the user card and provides a simple method to register or delete cards,  
and initialize the system, which is, one of the most convenient and safest door controller.  
And it is also featured by the 2-color LED indicator and the internal buzzer, enabling you to easily check the current mode  
and operation of the door lock.  
125 kHz Proximity Access Controller  
Up to 512 users including one Master ID can be registered  
Standalone (no application S/W required)  
Direct Control of the Door Lock  
Can select a lock device type from Power Fail Safe and Power Fail Secure  
Epoxy Molding  
Weatherproof  
English5  
 
product introduction  
WHAT’S INCLUDED  
Check if the following items are included in the product package.  
tˆš›Œ™Gjˆ™‹  
Master Card (x1)  
Keytag (x5)  
Main Module  
Bezel  
xœŠ’Gnœ‹Œ  
3.5 x 40mm Screws (x2)  
3.5 x 25mm Screws (x2)  
6 x 30mm Plastic Anchors (x2)  
Diode (X 2)  
(UF4004, 1N4001~4007)  
Quick Guide  
CD Manual  
6_ Product Introduction  
 
AT A GLANCE  
Front/Rear  
3
4
5
LED  
Displays the system operation status using red and green indicators.  
Fixing hole for wall-mounting.  
1
Fixing Hole  
2
Connection Cable  
Used to connect to the power or I/O cable.  
Port used to upgrade the firmware.  
Piezo buzzer.  
3
4
5
Program Port  
Buzzer  
English7  
 
product introduction  
CABLE COLOR SCHEME  
Item  
Cable Color  
Red  
Signal Line  
DC+12V  
Description  
+12V supplied  
Power  
Black  
GND  
Earth-Grounding for Power  
Select a Lock Type  
Yellow  
Blue  
AUX INPUT#1  
Door Contact Sensor  
Exit Button  
Input  
Output  
Door Sensor Connection Port  
Exit Button Connection Port  
Green  
Alarm Device Connection  
Port  
Purple  
White  
Alarm Out  
Door Lock device connection  
port  
Door Lock Out  
Gray  
Orange  
Brown  
Not used  
CABLE SELECTION  
Item  
Cable Type  
Power (DC +12V)  
Belden #9409, 18 AWG 2 Conductor, Unshielded  
Belden #9512, 22 AWG 4 Conductor, Shielded  
1
Door Contact Sensor  
Exit Button  
Sensor Input  
2
Belden #9514, 22 AWG 8 Conductor, Shielded  
Belden #9409, 18AWG 2 Conductor, Unshielded  
Door Lock  
3
Alarm Device  
8_ Product Introduction  
 
installation and external connection  
INSTALLATION  
10  
6-32 hole  
6-32 or M3 Screws  
1/2” hole  
6-32 hole  
Reader  
Module  
8.5  
- On a doorframe or the wall  
1. Drill a 1/2-inch (12.7 mm) hole onto the center of the doorframe or the wall where SSA-S1000 is installed, which  
makes room for the cable of the reader module.  
2. Drill two 0.3-inch (7.62 mm) holes: one on the point of 0.39 inch (10 mm) horizontally to the right, 1.74 inch  
(44.4 mm) vertically up from the center hole, and one on the point of 0.33 inch (8.5 mm) horizontally to the left,  
0.3 inch (7.62 mm) vertically down from the point.  
3. Insert the reader module cable into the center hole and secure the module using two screws inserted in the  
upper right and the bottom left corner, respectively.  
4. Insert the bezel of SSA-S1000 into the reader module and attach it by pressing the upper and lower corner of  
the bezel.  
BYPASS DIODE CONNECTION  
If you connected an inductor (door lock or alarm device) to the output relay, there should occur a voltage surge while the  
inductor was between turning on and turning off. If you do not connect a reverse diode to the relay, the voltage surge will  
cause damage to the electric circuit of the controller. To reduce this surge, it is recommended to connect the bypass  
diode to the relay.  
English9  
 
installation and external connection  
I/O CONNECTION  
Input Connection  
DOOR CONTACT (blue)  
Door Contact Sensor  
EXIT BUTTON  
(green)  
Exit Button  
PUSH  
DC +12V  
GND  
GND  
(black)  
DC +12V  
(red)  
DC 12V(+) POWER  
- To connect the power supply unit  
1. Connect the DC+12V to the red line.  
2. Connect GND to the black line.  
- To connect the Door Contact Sensor  
1. Connect the COM port of the sensor to the blue line.  
2. Connect the NO port of the sensor with the GND line.  
- To connect the Exit Button  
1. Connect one end of the button to the green line.  
2. Connect the other end of the button to GND.  
10_ Installation and External Connection  
 
Output Connection  
DOOR LOCK OUT  
(white)  
Door Lock  
ALARM OUT  
(purple)  
Alarm Device  
Lock Type Select  
(yellow)  
Cathode  
Anode  
1N4004 ~ 1N4007 or equiv.  
DC +12V  
GND  
DC 12V(+) POWER  
- To connect the power supply unit  
1. Connect the DC+12V to the red line.  
2. Connect GND to the black line.  
- To connect the door lock device  
1. Connect the plus(+) line of the lock device to DC+12V.  
2. Connect the minus(-) line of the lock device to the white line.  
- To connect the alarm device  
1. Connect the plus(+) line of the alarm device to DC+12V.  
2. Connect the minus(-) line of the alarm device to the purple line.  
- To specify the lock type  
POWER FAIL SAFE: Connect the yellow line to GND.  
POWER FAIL SECURE: Leave the yellow line in the floating state.  
English11  
 
system initialization & basic operations  
INITIALIZING THE SYSTEM BY SHORT-CIRCUITING  
Short-Circuit  
1. Turn off the product and short-circuit three lines: white line of  
the door lock device, green line of the Exit button, and yellow  
line of the lock type.  
White  
Door Lock  
2. When you turn the product back on, all of the LED indicators  
Green  
turn red or green, repeat turning on/off twice before being  
Exit Button  
completely turned off.  
Yellow  
Lock Type  
3. In the power-off condition, all LED indicators turn green  
bottom up in sequence.  
4. When you hear a beep 4 times, that indicates that the  
initialization is completed.  
Black  
Power  
Red  
If you initialize the system, all of the data settings will return to the factory default.  
M
BASIC OPERATIONS  
When the power is supplied  
1. All of the LED indicators will turn red or green, and repeat turning ON/OFF twice before being completely turned  
OFF. In the power-off condition, all LED indicators turn red bottom up in sequence.  
2. You will hear a beep once.  
When you present a registered card to the product or press the Exit button  
1. All LED indicators turn from red to green, and turn off top down in sequence before turning back red.  
2. Then, the door stays open for the specified time with the upper two indicators turning green, which indicates the  
door is open.  
3. You will hear a beep once.  
When you present an unregistered card to the product  
1. All LED indicators turn red, and repeat turning on/off twice before staying in ON.  
2. You will hear a beep twice.  
When you present a user card to the product while the door is open  
1. The two LED indicators from the top stay green, indicating the door is open; in the mean time, the other  
indicators reflect the authentication results.  
12_ System Initialization & Basic Operations  
 
TO REGISTER /DELETE MASTER ID  
SSA-S1000  
1. First turn off the product, and short-circuit two lines: purple line of  
Cable  
Alarm Out and blue line of the Door Contact Sensor.  
Blue  
2. When you turn the product back on, you will hear the beep twice while  
all of the LED indicators turn red, and repeat turning on/off twice before  
being completely ON; then the Master card will be deleted.  
Yellow  
Green  
Purple  
White  
Short-Circuit  
3. Upon deletion of the Master Card, you will hear a beep once and  
all of the LED indicators toggle between green and red twice  
before turning off; in this condition, they turn red from bottom up  
in sequence.  
Red  
DC12V  
Power  
4. When the deletion is completed, turn off the product.  
Connect the purple line of Alarm Out and the blue line of the Door  
Contact Sensor back to their original ports, respectively.  
Black  
GND  
5. When you turn the product back on, it recognizes and registers the first-read card as the Master Card. And  
if you present a registered user card to the product upon deletion of the Master Card, that card will be  
registered as the Master Card.  
If you present a registered user card after the Master Card is deleted, that card will be registered as the Master Card.  
M
TO REGISTER/DELETE ID CARD  
1. If you present the Master Card to the product, it will sound the beep  
once and the first three LED indicators from the top will turn green  
from the top.  
SSA-S1000  
MASTER CARD  
2. If you present a new user card to the product, it will sound the beep  
once and all of the LED indicators except for the first three ones from  
the top will turn from red to green. Then, they all turn off and turn  
back on bottom up in sequence. When all of the LED indicators turn  
back on, they will turn red except for the first three LED indicators  
from the top . Then, the user card will be registered.  
3. If you present a registered user card, the product will sound the beep twice and all LED indicators except for the  
first 3 from the top will turn red, and repeat turning on/off twice before being completely ON. Then the user card  
will be deleted.  
4. When you present the Master Card to the product after the user card is deleted, the product will sound the  
beep once and all of the LED indicators turn red, starting with the first three LED indicators from the top turning  
from green to red.  
If you present a registered user card after the Master Card is deleted, that card will be registered as the Master Card.  
M
English13  
 
troubleshooting  
TROUBLESHOOTING  
If the product does not function properly, please see the below for trouble shooting. If the trouble persists, please contact  
the SAMSUNG Customer Service near you.  
PROBLEM  
SOLUTION  
1) Check if the product works properly.  
The user card is not deleted.  
- If the product works properly and you have the Master Card  
c Read the Master Card.  
d Read the card to delete.  
e Read the Master Card again to switch to normal mode.  
f For more information about deleting user cards, refer to the ID registration and  
deletion section in this manual.  
- If you lost the Master Card  
c Turn off the product and short-circuit the purple and blue lines, then turn the  
product back on.  
d The Master ID will be deleted with a flashing LED indicator and beep.  
e When the Master card is deleted, turn off the product and restore the purple  
and blue lines to their respective original positions.  
f The very first card read by the product after turning on the product will be  
registered as the Master Card.  
g For deleting the ID once the Master Card is registered, refer to the ID  
registration and deletion section in this manual.  
h Turn off the product and short-circuit the purple and blue lines, then turn the  
product back on.  
i The Master ID will be deleted with a flashing LED indicator and beep.  
j When the Master card is deleted, turn off the product and restore the purple  
and blue lines to their respective original.  
k The very first card read by the product after turning on the product will be  
registered as the Master Card.  
The Exit button does not work at all.  
1) Check if the Exit button is connected to SSA-S1000 properly. (the Exit button  
should be used with a NO-type button)  
2) Check if the Exit button works normally.  
- Check the connection cable between the Exit button and SSA-S1000 for any  
disconnection or short-circuit.  
- Try to connect the two lines on the Exit button.  
c If SSA-S1000 responds when you press the Exit button  
Replace the Exit button as it is defective.  
d If SSA-S1000 does not respond at all  
Initialize the product as it is damaged or malfunctions. (Initializing the product  
will lose all user data.)  
3) If the trouble persists after following the procedures above, contact a designated  
service center.  
14_ troubleshooting  
 
product specifications  
PRODUCT SPECIFICATIONS  
Item  
SSA-S1000  
Users  
512 Users  
Power / Current  
Reading Time (Card)  
Door Open Time  
Input Port  
DC 12V / Max.110mA  
30ms  
5sec. (Fixed)  
3ea: Exit Button, Door Sensor, Lock Type Select [Power fail Safe / Power Fail Secure]  
2ea : TR Output / DC 12V. Rating Max. 300mA Alarm Output, DC 12V. Rating Max.  
1A Lock Output  
Output Port  
LED Indicator  
9 LED Indicators (Red and Green)  
Piezo Buzzer  
Beeper  
Operating Temperature  
Operating Humidity  
Color / Material  
-20°C to +50°C  
10% to 90% Relative Humidity Non-Condensing  
Silver with Black/ Polycarbonate  
Dimension  
(W x H x D(mm))  
45.0 x 122.0 x 25.0  
130g  
Weight  
English15  
 
Correct Disposal of This Product (Waste Electrical & Electronic Equipment)  
(Applicable in the European Union and other European countries with separate collection systems)  
This marking on the product, accessories or literature indicates that the product and its electronic accessories (e.g.  
charger, headset, USB cable) should not be disposed of with other household waste at the end of their working life. To  
prevent possible harm to the environment or human health from uncontrolled waste disposal, please separate these  
items from other types of waste and recycle them responsibly to promote the sustainable reuse of material resources.  
Household users should contact either the retailer where they purchased this product, or their local government office, for  
details of where and how they can take these items for environmentally safe recycling.  
Business users should contact their supplier and check the terms and conditions of the purchase contract.  
This product and its electronic accessories should not be mixed with other commercial wastes for disposal.  
Correct disposal of batteries in this product  
(Applicable in the European Union and other European countries with separate battery return systems.)  
This marking on the battery, manual or packaging indicates that the batteries in this product should not be disposed of  
with other household waste at the end of their working life. Where marked, the chemical symbols Hg, Cd or Pb indicate  
that the battery contains mercury, cadmium or lead above the reference levels in EC Directive 2006/66. If batteries are  
not properly disposed of, these substances can cause harm to human health or the environment.  
To protect natural resources and to promote material reuse, please separate batteries from other types of waste and  
recycle them through your local, free battery return system.  
AB82-02558A  
 

QVS Surge Protector PP134C User Guide
Raritan Computer Switch MXU28 User Guide
Raymarine GPS Receiver Platinum Chart Card User Guide
Roberts Radio Portable Radio RD 41 User Guide
Roland DJ Equipment SL 20 User Guide
Samsung DVD Player DVD C601 User Guide
SanDisk Computer Drive 4GBMicroSDHC User Guide
Sanyo Air Conditioner C4272R S C User Guide
Scientific Atlanta Satellite TV System 4240C User Guide
Sears Cooktop 46725 User Guide