Gas Inserts
E33 Gas Insert
E33 Gas Insert
Model
E33-NG1
Natural Gas
E33-LP1
Fuel Type
Propane
Minimum Supply Pressure
Manifold Pressure - High
Manifold Pressure - Low
Orifice Size -Altitude 0-4500 ft.
5” W.C. (1.25 kPa)
3.8” W.C. (0.95 kPa)
1.1” W.C. (0.27 kPa)
#31 DMS
12” W.C. (2.99 kPa)
11” W.C. (2.74 kPa)
2.9” W.C. (0.72 kPa)
#50 DMS
Minimum Input
Altitude 0-4500 ft. (0-1372m)
20,000 BTU/h
(5.86 kW)
19,000 BTU/h
(5.57 kW)
Maximum Input
Altitude 0-4500 ft. (0-1372m)
38,000 BTU/h
(11.14 kW)
35,500 BTU/h
(10.40 kW)
Vent Sizing
3” Co-linear
3” Co-linear
Approved Venting Systems
Flex Vent Systems:
FPI AstroCap™ Flex Vent
A
Minimum Fireplace Dimensions
B
The minimum fireplace dimensions for the FPI gas fireplace insert are
shown in the following diagrams:
C
G
F
30°
M
L
J
H
D
E
K
N
Dimension Description
E33
A
B
C
D
E
F
G
H
I
Faceplate Width
Faceplate Height
Unit Width
45-9/16” (1157mm)
31-1/8” (791mm)
32-1/4” (819mm)
23-13/16” (605mm)
16-3/4” (426mm)
11-1/4” (286mm)
1-3/8” (35mm)
23” (583mm)
Dimension Description
Contour Faceplate
24-3/16” (614mm)
32-1/4” (819mm)
17” (432mm)
Unit Height
J
Height
Unit Depth
K
L
Width
Faceplate to Vent Centerline
Faceplate Depth
Depth
M
N
Max. Lintel Bar Depth
Rear Width
8” (203mm)
Height to Vent Collar
25” (635mm)
Optional or Standard Front Depth
N/A
June 2007 Regency Product Specifications Book
127
|