Quick Start Guide
AirborneDirect™ Industrial Serial Device Server
ABDG-SE-IN5410/IN5420
Revision v2.1
February 2011
Document Number: 100-8106-210
Kit Contents:
Upon receiving the kit please check that you received the following:
ABDG-SE-IN5410 or ABDG-SE-IN5420 Unit
2dBi, 2.4Ghz 50 ohm, omni-directional antenna
Quick Start Guide
5 VDC power supply (optional, included only if ordered as an accessory)
Airborne Direct software and documentation CD
If any of the above contents are missing or appear damaged please contact Quatech Sales support directly at (800) 553-1170 or
What you will need:
To evaluate the unit you will need the following components and facilities:
ABDG-ET-IN50X0 unit with included antenna attached.
Laptop or desktop system with an Ethernet port.
5-36 VDC power for terminal block attachment, or an AC power outlet for optional ABDG-SE-IN5410/IN5420 power supply.
802.11b/g network for testing the unit, either AdHoc or Infrastructure (Access Points) mode. The test network configuration must be
known. Required information will include:
o
o
o
o
SSID (Wireless network name).
Security settings (WEP, WPA, WPA2, etc.).
Security credentials (passphrase, key or certificates).
Static IP address, Subnet Mask and Gateway address if static IP addresses are used on the test network.
A web browser on the laptop top or desktop (MS Explorer, Firefox, Opera and Chrome v4.0 are supported).
CAT5 Ethernet cable for connecting the Airborne™ device to the laptop or desktop.
Serial cable to connect Airborne™ device to host system.
AirborneDirect™ Serial Device Server Quick Start Guide
Quatech, Inc.
Right Click the Unmanaged Device then:
1. Select Change Management State
2. Select Manage OEM-Cfg1
3. Select Device OEM-Cfg1 is Factory Default
8
The devices status will move to managed and the device will be displayed under the device type/group it
belongs too. Right click the device and then:
1. Select Connectivity Tools
2. Select Launch Web Browser for OEM-Cfg1
9
Opening web page shows adapter status.
Links to the available configuration options are identified in the left hand menu. The top menu bar
provides access to different operations that can be performed by the AirborneDirect™ device. Please
refer to the User’s Manual for a full description of how to use the web interface.
10
Using Express Setup:
If this is the first time you have configured the device the Express Setup page will be displayed. This
page provides access to the critical configuration items needed to get the ABDG up and running quickly.
See Express Setup Configuration Page section for details on how to configure the device.
11
12
13
14
Please refer to the User’s Manual for complete details on ABDG device configuration.
When the Reboot button is pressed the unit will restart and install new settings. This may take 15-20
seconds. Please refresh the web interface after the boot cycle has completed.
When configured correctly the LED pattern should match the following:
ABDG-SE-IN5XXX
COMM:
No TCP Connection
Off
TCP Connection
Green
LINK :
POST:
Green
Green
Green
Green
POWER:
Blue
Blue
To use the adapter on the wireless network, address all traffic to the IP address of the wireless interface
of the ABDG-SE- IN5XXX. This address is listed in the home page of the web interface.
100-8106-210
3
February 2011
AirborneDirect™ Serial Device Server Quick Start Guide
Quatech, Inc.
Express Setup Configuration Page
When the devices web interface is accessed for the first time an Express Setup page will be shown. This page is designed to allow a quick device
set-up by presenting the most popular device configuration options in a single location. For more advanced configurations the full set of options
are available in the feature links (left-hand column).
The Express Setup web page will display the necessary fields based upon the selections made during configuration. The Express Setup page
looks like (Figure 1):
Figure 1 - Express Setup Page
To configure the device for operation each field must be configured correctly. The following steps should be taken to configure the device
(Note: not all fields will be visible):
Table 1 - Express Page Setup
Step
Description
Navigation Bar
You will see a group of fields under the banner of WLAN
Parameters.
Select Configuration
Feature Link
This step is optional. If this is the first time the device has been
configured this page will automatically be displayed.
Select Express Setup
Select Discovery OEM Device Name
This parameter allows you to name the device uniquely or
group into a functional set. When device discovery is used this
name identifies the found device.
If you wanted to uniquely identify the device you could mark it
with a label e.g. Dev1, and then enter Dev1 in this field. When
the device is found it will identify itself as Dev1.
Alternately you could indicate the type of equipment the device
is attached to e.g. Haas TL-2 (CNC Turning Center), by giving
the unit a name like Haas_TL_2. When discovered you can then
identify the device you are accessing.
Enter the text string is you wish to change the default value.
This field is optional.
Select Radio Startup Mode
Select On from the drop down menu for the radio to operate.
100-8106-210
4
February 2011
AirborneDirect™ Serial Device Server Quick Start Guide
Quatech, Inc.
Step
Description
Select Wireless LAN Connection Type If you are using Access Points make sure this is set to
Infrastructure from the drop down menu.
If you want to use AdHoc set this accordingly. Additional
settings may be required to fully configure for AdHoc mode.
Please refer to the User’s Manual for details.
Select SSID
Enter the name of the wireless network you wish to access. This
field is case sensitive.
Select Wireless LAN Security Type
Select the security type the wireless network you wish to access
is using. Depending upon the option you choose you may have
to enter additional information. Once you have selected the
security type the required inputs will be made accessible by un-
graying the fields that must be completed.
If the security type is not in the available selections, more are
available in the WLAN Security Settings page. If you choose to
use this page make sure you commit the changes you have
already made before moving to the WLAN Security Settings
page.
Select WLAN DHCP
If your WLAN network uses DHCP to assign IP addresses to the
wireless clients, select Enabled from the drop down menu.
If you are using static IP addresses select disabled from the
drop down menu. WLAN Static IP and WLAN Subnet Mask
will need to be entered.
Select Ethernet DHCP
If the Ethernet network connected to the Ethernet port uses
DHCP to assign IP addresses to the wired clients, you should
select Enabled from the drop down menu.
If you are using static IP addresses you should select Disabled
from the drop down menu. Ethernet Static IP and Ethernet
Subnet Mask will need to be entered.
Important: This field is only used if the Ethernet interface is
set as a client (default for Serial devices). If set as a router the
field is ignored. See the User’s Manual for a full description of
configuring the unit as an Ethernet router.
Select WLAN Static IP
This field defines the static IP address for the wireless interface.
This address is only used if the WLAN DHCP is disabled or
DHCP failed.
Default: 192.168.10.1
Select WLAN Subnet Mask
This field defines the subnet mask used by the wireless
interface.
This mask is only used if the WLAN DHCP is disabled or DHCP
failed.
Default: 255.255.255.0
Select Ethernet Static IP
Select Ethernet Subnet Mask
Press Commit [Button]
This field defines the static IP address for the Ethernet
interface. When configured as a serial device server (Ethernet
interface is in client mode) this address is only used if the
Ethernet DHCP is disabled or DHCP failed.
Default: 192.168.2.100
This field defines the subnet mask used by the Ethernet
interface. When configured as a serial device server (Ethernet
interface is in client mode) this mask is only used if the
Ethernet DHCP is disabled or DHCP failed.
Default: 255.255.255.0
Saves changes to the device.
Optional
Reloads the Express Settings page. Select this is you have
further configuration options to change.
Press Reload [Button]
100-8106-210
5
February 2011
AirborneDirect™ Serial Device Server Quick Start Guide
Quatech, Inc.
Step
Description
Optional
Restarts the device. After the device as rebooted it will attempt
to authenticate to the configured network. As long as the
network is in range the wireless interface will connect.
Press Restart [Button]
If the network is using DHCP then an IP address will be
assigned to the WLAN interface and IP connectivity is possible
over the WLAN network.
If the network is using static IP addresses it will be necessary to
configure the network interface, see the next step.
The web interface supports advanced configuration of the device through the additional pages available. The following sections provide
guidance on how to use these pages for specific configurations.
Table 2 – LED Indicators
LED
Color
Airborne Device State
Adapter is not powered.
POWER
Adapter is powered.
POST
Adapter is not powered.
Adapter failed Power On Self Test (POST) and is not configured for
wireless communication.
Adapter passed POST but is not configured for wireless network
communication.
Adapter passed post and is configured for wireless communication.
Adapter is not powered.
LINK
(Periodic Blinking) Adapter is searching for a valid network (Access Point)
that matches device’s configuration.
Adapter has successfully associated with an Access Point.
COMM
If Power LED is also Off then Adapter is not powered.
If Power LED is On then:
No TCP session from WLAN or Ethernet interface has been
established.
A TCP connection to the adapter has been established from the Wireless
or Ethernet interfaces but no traffic has been detected.
100-8106-210
6
February 2011
Serial Port Pin Out
Figure 2 - DE-9 Connector Pin-out
Table 3 – Serial Port Pin Definition
RS232 (DTE)
Port 1 & 2 (Default)
Pin
RS422/485
1
2
3
4
5
6
7
8
9
No Connect
No Connect
RxD+
RxD
TxD
TxD+
No Connect
GND
No Connect
GND
No Connect
RTS
RxD-
No Connect
No Connect
TxD-
CTS
No Connect
Serial Port Defaults Settings:
Setting
Port 1 (DTE)
Port 2 (DTE)
BAUD
9600
None
8
9600
None
8
Parity
Stop Bits
Data Bits
1
1
Flow Control
Serial Default Mode
Input Buffer Size (Bytes)
Serial Escape Mode
None
Listen
1460
ON
None
Listen
1460
ON
Second Serial Port
If you have purchased the ABDG-SE-IN5420 device it is possible to configure the second serial port using the web interface. Repeat step 10 in
the Getting Started section, however select the Serial Port 2 Settings link and configure the appropriate parameters.
AirborneDirect™ Serial Device Server Quick Start Guide
Quatech, Inc.
5675 Hudson Industrial Parkway
Hudson, OH 44236
Tel: 330.655.9000
800.553.1170
©2010-2011 Quatech, Inc. All rights reserved.
100-8106-110G
8
4/27/2010
|